| Thermal
Resistance: |
At
a pressure of 14 psi (appr. 1 kp/cm²) the thermal
resistance is 0,19 K/W cm², at a pressure of 100
psi (appr. 1 kp/cm²) 0,07 K/W cm². For example
in nmounting a peltierelement with an area of 16 cm²
the resitance is 0,07 /16 = 0,0043 K/W. As the pressure
in mounting a peltierelement is higher than 100 psi you